Step 6 - Device Configuration; Automatic Or Advanced Setup - Datalogic Matrix 300N Series Product Reference Manual

Hide thumbs Also See for Matrix 300N Series:
Table of Contents

Advertisement

STEP 6 - DEVICE CONFIGURATION

Automatic or Advanced Setup

Automatic Setup
reading distance (for software adjustable focus liquid lens models), and code definition
parameters to obtain the most stable decoding conditions for a single code symbology
based on the images presented to the reader. It can be set to include Image Filters if
necessary. See the table below for codes and filters managed by Automatic Setup. Auto-
matic Setup is especially useful for DPM applications.
Enabled 1D Codes
CODE 128
EAN 128
CODE 39
CODE 93
CODABAR
PDF417
MICRO PDF417
GS1 DATABAR
GS1 DATABAR STACKED
GS1 DATABAR LIMITED
GS1 DATABAR EXPANDED
GS1 DATABAR EXPANDED
STACKED
UPCEAN FAMILY EAN13
UPCEAN FAMILY EAN8
UPCEAN FAMILY UPCA
UPCEAN FAMILY UPCE
Advanced Setup
and manual focusing adjustment, and code definition parameters that can be fine-
tuned semi-automatically and manually to obtain the best results for applications of any
complexity.
NOTE
provides an automatic procedure for setting: optical/illumination,
provides access to the complete array of optical/illumination, software
If your application requires multiple code symbologies, multiple image
settings, Code Grading or other parameter settings for decoding, then use
the Advanced Setup, see Advanced Setup for Software Adjustable Focus
Models (Liquid Lens).
STEP 6 - DEVICE CONFIGURATION
Enabled 2D Codes
DATAMATRIX ECC 200
QR
MICRO QR
AZTEC
MAXICODE
DOTCODE
PRODUCT REFERENCE GUIDE
Enabled Filters
ERODE 3x3, 5x5 and
7x7
DILATE 3x3, 5x5 and
7x7
SMOOTHING
13

Advertisement

Table of Contents
loading

Table of Contents