BM150 Backup and Restore Procedure

The Backup and Restore functions are valid for any application layout type (point-to-
point, network, etc.) using CBX500 connection boxes through the BM100 Backup mod-
ule (required accessory for BM150 installation).
The Backup and Restore functions are managed through the BM150 display and keypad
and therefore are disabled at the BM100 Backup/Restore button.
If it ever becomes necessary to replace the reading device it can be quickly configured
through the restore procedure.
BM150 provides complete backup and restore functions (Configuration and Environ-
mental parameters) with the following difference:
For Single Readers or individual ID-NET Slaves:
For Master Readers in ID-NET Master/Slave networks:
CAUTION
The Slaves must always be configured with the same network baud rate as the Master
for correct functioning including performing Backup and Restore procedures.
Backup and Restore functions cannot be interrupted once started.
To perform Backup:
1. Make sure the Write Protection switch on the BM100 is unlocked.
2. Select the Backup item from the Extended menu and press the Enter key.
3. When the procedure is complete a message appears on the display showing the
4. Set the Write Protection switch to locked.
To perform Restore:
1. Select the Restore item from the Extended menu and press the Enter key.
2. When the procedure is complete a message appears on the display showing the
Backup and Restore functions provide parameter storage including all configura-
tion jobs present on the reader.
Backup and Restore functions provide parameter storage of only the Startup Con-
figuration for the Master and all Slaves present in the network.
For Master/Slave networks any other configurations (jobs) stored in the
device memory will not be backed up. Therefore upon a restore, all jobs
other than the startup configuration will be overwritten (erased). It is
strongly recommended to save all configurations to backup files.
results (Backup OK 1 File Saved or an error message).
results (Restore OK 1 File Restored or an error message).