Technical Features; Electrical Features - Datalogic Matrix 300N Series Product Reference Manual

Hide thumbs Also See for Matrix 300N Series:
Table of Contents

Advertisement

CHAPTER 11

TECHNICAL FEATURES

ELECTRICAL FEATURES

Electrical Features
Power
Supply Voltage
Consumption
Communication Interfaces
Main: RS232, RS422 Full-duplex
Auxiliary: RS232
ID-NET
Ethernet (Built-in)
supported application protocols
Inputs
Input 1(External Trigger) and Input 2
Max. Voltage
Max. Input Current
a
Outputs
Output 1, 2 and 3
V
I
OUT (
LOAD = 0 mA) Max.
V
I
OUT (
LOAD = 100 mA) Max.
I
LOAD Max.
a. when connected to the CBX connection boxes the electrical features for Output 1 and 2 become the following:
Opto-isolated; V
= 30 Vdc max.; I
CE
V
= 1 Vdc max. @ 10 mA; P
CE saturation
210
MATRIX 300N
4xx-01x models
7xx-01x models
10 to 30 Vdc
0.7 to 0.2 A
TCP/IP, EtherNet/IP, Modbus TCP, PROFINET-IO
Opto-coupled and polarity insensitive
NPN or PNP short circuit protected;
= 40 mA continuous max.; 130 mA pulsed max.;
CE
= 90 mW Max. @ 50 °C ambient temp.
D
4xx-04x models
PoE Device 48 Vdc
2400 to 115200 bit/s
2400 to 115200 bit/s
Up to 1 Mbaud
10/100 Mbit/s
30 Vdc
10 mA
NN available for 7xx-0xx models
30 Vdc
3 Vdc
100 mA
0.13 W max

Advertisement