Outputs - Datalogic DS1500 Reference Manual

Datalogic compact laser scanner reference manual
Table of Contents

Advertisement

INSTALLATION
An anti-disturbance hardware filter is implemented on the External Trigger input (< 5
milliseconds delay).
An additional 15 ms (typical) delay can be implemented through a dedicated software
parameter (refer to WinHost Help On Line).
2.3.5

Outputs

Two general purpose outputs are available. These outputs can only be connected as
open collector configurations. The following pins are present on the 15-pin connector
of the scanner:
Pin
7
14
5
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No
Read, Right, Wrong, or a combination). Refer to the WinHost Help On Line.
By default, OUT1 is associated with the No Read event, which activates when the
code signaled by the external trigger is not decoded, and OUT2 is associated with
the Right event, which activates when the code is correctly decoded.
These outputs are both level and pulse configurable.
DS1500
V
max = 40 Vdc
CE
I max = 20 mA continuous
Name
Function
OUT1+
output 1 +
OUT2+
output 2 +
GND
output reference
+
7/14
GND
5
Figure 14 - DS1500 Output Connections
USER INTERFACE
Vext 40Vdc max., 20 mA max.
Ground
2
19

Hide quick links: