Multidata ID-NET Network Configurations

The Multidata ID-NET network communications between Master and Slave are man-
aged by the application job (configuration) using the pass-through feature. A pre-config-
ured job is loaded with the correct pass-through settings for both the Master and Slaves
when the Default Multidata Configuration is selected from the Internal Network Setting
feature.
1. Complete the configuration of all the application parameters (including Image Set-
The jobs must not be cloned because the Master and Slaves have different input/output
communication channels. The readers are also working independently from each other,
often on separate stations with different code reading requirements, different operating
modes, etc.
2. Connect to each Slave reader via Ethernet (see note below), and set all the config-
tings) and save them to the Master with an application specific name.
Optionally, checking the Save on Slave Device box can be helpful to save all the
current individual Slave configurations with the new configuration name. This
does not clone any parameters. If not checked, Slave configurations will remain as
Temp configurations and you will be warned that changes to the Master have not
been saved to the Cluster.
For Multidata configurations, the option to Clone Master configuration on Slaves
must not be
checked.
Figure 94 - Saving Multidata Configuration to Master
uration parameters of each Slave device.
INTERNAL NETWORK CONFIGURATIONS