debouncer. Different trigger modes can set various trigger parameters, and their relation is shown
below.
If the frame trigger is enabled, the relation between trigger source and trigger related
parameters is shown below.
Trigger Source
Parameters
Acquisition Burst Frame
Count
Trigger Activation
Trigger Delay
Frame Trigger Cache
Trigger Debouncer
If the line trigger is enabled, the relation between trigger source and trigger related
parameters is shown below.
Trigger Source
Parameters
Trigger Activation
Trigger Delay
Line Trigger Cache
Trigger Debouncer
7.7.1 Acquisition Burst Frame Count
If the camera enables the frame trigger, you can set the acquisition burst frame count. Click
Acquisition Control > Acquisition Burst Frame Count, and enter Acquisition Burst Frame Count
according to actual demands. Its range is from 1 to 1023.
Camera Link Line Scan Camera
Table 7-3 Trigger Source and Trigger Related Parameters
Software
Hardware
Trigger
Trigger
√
×
√
√
×
Table 7-4 Trigger Source and Trigger Related Parameters
Hardware
Shaft Encoder
Trigger
Control
√
√
√
√
User Manual
·
Frequency
Converter
Control
√
√
√
√
√
√
√
√
√
√
Frequency
Converter
Control
√
√
√
√
√
√
×
×
29
Frame
Free Trigger
Grabber
Trigger
√
√
√
√
√
Frame
Free Trigger
Grabber
Trigger
√
√
√
√
√
√
√
√
√
√
√
√
√
Need help?