Number of visible wire breaks on a rotation-resistant hoist rope
The rope section runs over a rope disc or on a drum wound as a single layer
Number of
load-bearing
outer wires
101-120
121–140
101-120
121–140
The rope section is running on a drum wound as multiple layers
101-120
121–140
101-120
121–140
Maintenance manual
GMK5200-1
The tables show by rope diameter the number of wire breaks in a
length 6 times and 30 times the rope diameter which if reached would
require replacement of the rope.
Familiarise yourself with DIN ISO 4309:2013-06 (rotation-resistant ropes).
This table applies only to the hoist ropes fitted as initial equipment and
original replacement ropes!
∅ 13 mm
to
to
78 mm
390 mm
3
5
3
5
∅ 19 mm
to
to
114 mm
570 mm
3
5
3
5
∅ 13 mm
to
to
78 mm
390 mm
5
10
6
11
∅ 19 mm
to
to
114 mm
570 mm
5
10
6
11
∅ 16 mm
to
96 mm
3
3
∅ 22 mm
to
132 mm
3
3
∅ 16 mm
to
96 mm
5
6
∅ 22 mm
to
132 mm
5
6
3 302 746 en
Maintenance work on the superstructure
∅ 17 mm
to
to
480 mm
102 mm
5
3
5
3
∅ 24 mm
to
to
660 mm
144 mm
5
3
5
3
∅ 17 mm
to
to
480 mm
102 mm
10
5
11
6
∅ 24 mm
to
to
660 mm
144 mm
10
5
11
6
8.8 Hoist ropes
to
510 mm
5
5
to
720 mm
5
5
to
510 mm
10
11
to
720 mm
10
11
s
8 - 57