Changing The Ventilation Filter - Manitowoc Grove GMK 5200-1 Maintenance Manual

Table of Contents

Advertisement

7.15.5
Reducing the
interval
Spare parts and
tools
Prerequisites
O
Maintenance manual
GMK5200-1

Changing the ventilation filter

Under difficult operating conditions – at extremely sandy or dusty loca-
tions – you must change the ventilation filters earlier than normal.
Designation
Filter
– The engine must be switched off and secured against unauthorised use;
à
p. 2 - 3.
Risk of damage to the environment from filter residues.
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.
Remove the cover (1).
Change the filter (2) and fasten the cover.
3 302 746 en
Maintenance work on the carrier
7.15 Hydraulic system
Quantity
GROVE part no.
1
03324588
M 12
7 - 105