Maintenance work on the carrier
7.16 Central lubrication system
Topping up
S
7 - 120
Risk of damage to the central lubrication system.
Cleanliness is of the utmost importance when handling grease and filling
pumps.
Do not remove the caps from the opening and filling pump until immedi-
ately before refilling the grease. This prevents dirt particles from getting
into the grease and damaging the central lubrication system.
Switch on the ignition.
Fill the grease container as follows:
1 Filling pump tool set
You must install the connector from the
toolbox.
2 Filling pumps for lubrication nipples
Attach the respective filling pump to the
connection (1) or (2).
Remove the cap (3).
Press the button (4) for approx. 2 seconds
once.
Bolt the cover (3) on.
Intermediate lubrication will be triggered.
Fill the grease container up to the max.
mark.
Remove the filling pump, wipe away any
excess grease and close the holes.
3 302 746 en
Maintenance manual