Changing filters
3 and 4
O
Maintenance manual
GMK5200-1
Risk of damage to the environment from filter residues.
Store used hydraulic oil filter inserts in suitable receptacles and have them
disposed of properly by qualified personnel.
3 302 746 en
Maintenance work on the carrier
Remove the receptacle (1).
Place the filter in a receptacle.
Change the filter (2).
Replace any defective parts, where neces-
sary.
Fill the receptacle with clean oil.
Put the receptacle on and tighten it.
Change the filter on the opposite side in the
same way.
7.15 Hydraulic system
7 - 117