DS1 T
OTAL
C
P
URRENT
ERF
T
HRESHOLD
61200305L1-1
C
LCV T
URRENT
HRSH
The DS1 performance monitor Threshold Value for the Current 15 minute
Line Code Violations (LCV) parameter. The default value is 13,340 for an
approximate BER level of 10E-5.
Write security: 2; Read security: 5
Defines performance threshold values for DS1 Line and Path statistics. If a
statistic value exceeds its threshold value, then the corresponding Alert
Trap will be sent if the alert event is armed and Alert Taps are enabled.
These threshold values apply to all DS1 interfaces in the system.
T
ES T
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Errored Sec-
onds (ES) parameter. The default value is 648 for an approximate BER level
of 10E-5.
T
SES T
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Severely
Errored Seconds (SES) parameter. The default value is 100 for an approxi-
mate BER level of 10E-5.
T
SEFS T
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Severely
Errored Framing Seconds (SEFS) parameter. The default value is 17 for an
approximate BER level of 10E-5.
T
UAS T
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Unavailable
Seconds (UAS) parameter. The default value is 10 for an approximate BER
level of 10E-5.
T
CSS T
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Controlled Slip
Seconds (SES) parameter. The default value is 4 for an approximate BER
level of 10E-5.
T
PCV T
(D4)
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Path Code Vio-
lations (PCV) parameter, when the Line Type is Super Frame (AT&T D4 for-
mat) DS1. The default value is 691 Framing Errors for an approximate BER
level of 10E-5.
T
PCV T
(ESF)
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Path Code Vio-
lations (PCV) parameter, when the Line Type is Extended Super Frame
(ESF) DS1. The default value is 132,960 CRC errors for an approximate BER
level of 10E-5.
T
LES T
OTAL
HRSH
The DS1 performance monitor Threshold Value for the Total Line Errored
Seconds (LES) parameter. The default value is 648 for an approximate BER
level of 10E-5.