Zones for back-end switches

Create zones that have one appliance initiator and one storage controller port. Storage arrays
may have one port per controller
appliance initiators connect to the switches as follows:
Table 7
connected to the switch (a total of 28 storage zones). For each storage controller port
connected to the switch, create four zones—one for each appliance initiator
can connect a maximum of 14 storage arrays to a non–cascaded 16–port switch (two initiators
multiplied by 14 storage arrays).
Table 7: Storage zones for back–end switches
Storage
zone
0
1
X
2
3
X
4
5
X
6
7
X
8
9
X
10
11
X
12
13
X
14
15
X
16
17
X
18
19
X
20
96
From node 0:
— I1 connects to port 0 on back-end switch 1.
— I2 connects to port 1 on back-end switch 2.
From node 1:
— I1 connects to port 0 on back-end switch 2.
— I2 connects to port 1 on back-end switch 1.
lists the zones you create for two storage arrays (with one port per controller)
1
2
3
4
5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
(Figure
18) or two ports per controller
Switch ports
6
7
8
9
X
X
X
X
X
X
X
X
Continuous Access Storage Appliance Installation and Maintenance Guide