Replacing and Configuring Appliance Components
Reconfiguring the host bus adapters
This section describes the procedures for:
Replacing an HBA
This section describes the procedures for:
The HBA replacement specifications follow:
Replacing the shared storage initiator HBA
To replace the shared storage initiator HBA:
1. Power down the appliance node with the defective adapter.
2. Disconnect the storage cables from this appliance node.
3. Disconnect the shared storage Fibre Channel cables from the defective adapter.
4. Replace the defective adapter.
5. Connect the shared storage Fibre Channel cables to the new adapter.
Note:
6. Power up the appliance node.
Note:
comply, see
continuing with this procedure.
7. Click OK when the following message is displayed:
8. Ensure the hp OV CASA Console window is open in administrative mode.
9. Press Alt+C to open a command prompt window.
10. To locate the Shared Disk SCSI Address parameter in the sanlink log, enter:
112
Replacing an HBA
Resetting the firmware parameters for an initiator HBA
Updating the HBA firmware
Replacing the shared storage initiator HBA
Replacing a target/initiator HBA
Part number—A7546-69001
Description—QLogic 2344F four–port full– profile HBA
Assembly number—A7546-60001
Do not connect the storage cables to the appliance node at this time.
Ensure that the new adapter's BIOS complies with the current SANOS version. If it does not
"Resetting the firmware parameters for an initiator
At least one service or driver failed during system startup...
c:\sanlink\www\logs\sanlink.log | find "verifySharedDiskScsiAddress"
Continuous Access Storage Appliance Installation and Maintenance Guide
HBA" on page 115 before