Resetting the firmware parameters for an initiator HBA
To reset an initiator HBA's firmware parameters:
Note:
DPF setup.
1. Reboot or turn on the appliance node.
2. When prompted, press Ctrl+Q.
3. Select the first adapter and press Enter.
4. Click Configuration Settings and press Enter.
5. Click Host Adapter Settings and press Enter.
6. To select a parameter, highlight the parameter name and press Enter. Then specify the
7. Press Esc to return to the Configuration Settings menu
8. Click Advanced Adapter Settings and press Enter.
Continuous Access Storage Appliance Installation and Maintenance Guide
The firmware parameters for the target HBAs are set when the target driver loads during RPIC
The Select Host Adapter menu opens, listing the available HBAs in scan order.
The Fast!UTIL Options menu opens.
value for the parameter listed below.
Host Adapter Bios—Disabled
Frame Size—2048
Loop Reset Delay—5
Adapter Hard Loop ID—Disabled
Hard Loop ID—0
Spin up Delay—Disabled
Connection Option—2
Fiber Channel Tape Support—Disabled*
Data Rate—2
An asterisk (*) indicates that you must change the parameter to the value listed.
Parameters without an asterisk show the default value; do not change this value.