Hp Storageworks Virtual Array 7110; Technical Specifications - HP Open View Installation And Maintenance Manual

Continuous access storage appliance
Table of Contents

Advertisement

HP StorageWorks Virtual Array 7110

The Virtual Array 7110 (va7110) is the shared storage array between the two nodes. It contains
the configuration information that both nodes monitor and maintain. To avoid data corruption,
a file–sharing system ensures that only one node has write access to the array at any time.
For more information on the array, refer to the HP StorageWorks Virtual Arrays va7000
Family User and Service Guide. This guide is available on the HP web site at the following
address:
http://h20015.www2.hp.com/content/common/manuals/lpg60187/lpg60187.pdf

Technical specifications

Native capacity
External I/O ports
Sustained performance
Memory cache
Cache (internal)
Current (maximum two
power inputs)
Power consumption
Power supply
Dimensions (H x W x D)
Weight (shipping)
Temperature range
Humidity range
Continuous Access Storage Appliance Installation and Maintenance Guide
Type
6.5 TB
Two 2 GB/s or 1 GB/s Fibre Channel ports
164 MB/s read
Up to 2 GB mirrored cache
Up to 2 GB per controller
8.2 A @ 100 VAC
3.4 A @ 200 VAC
473 W @ 120 VAC
457 W @ 240 VAC
100-240 Vac auto-ranging, 50-60Hz
5.0 x 17.6 x 20.0 inches
(12.7 x 44.7 x 50.8 cm)
101.5 pounds
Operating: 5º C to 35º C (41º F to 95º F)
Storage: –40º C to 70º C (–40º F to 158º F)
Operating: 15 to 80% @ 28º C (dry bulb)
Storage: 5 to 95% @ 149º F/ 65º C (dry bulb)
Appliance Components