Replacing and Configuring Appliance Components
25. Press Alt+C to open a command prompt window and enter:
26. Click Registry > Import Registry File.
27. Select the tempPeerReg.reg file from the c:\ drive and click Open.
28. Click OK when the Registry Editor window opens.
29. Close the Registry Editor window.
30. Ensure that all cables are connected to the appropriate node ports.
31. From the hp OV CASA Console window, click service viewer.
32. Select one of the following services and set the startup type to Automatic:
33. Reboot the node.
34. After the node reboots, verify that the services have started successfully.
35. From the console window, click sanos admin > launch.
36. Log in to sanosadmin using the SANOS administrator account information entered in
37. To verify that the nodes can detect each other, enter:
Note:
name of the mirror and proxy nodes.
38. Repeat step 37 on the other node.
39. If you modified the appliance configuration and/or user–related databases after the latest
40. Install the appropriate back–end path failover software on the appliance node, if
110
cd \
copy \\PeerInterLinkAddress\C$\tempPeerReg.reg
regedit
The Registry Editor window opens.
The Import Registry File dialog box opens.
The Services window opens.
Identification and Authorization Server
RPIC DPF
sv3000 Management Server (SMS)
Tomcat
VA Status Monitor (VSM)
WebServer
Repeat this step for each service listed.
The sanosadmin window opens.
step 22.
get node
If the customer uses IP mirroring, the get node command displays the IP address and
backup, you will not see those changes on the node. You must enter the changes manually
using either sanosadmin or the user interface.
applicable.
Continuous Access Storage Appliance Installation and Maintenance Guide