Lift System Troubleshooting - Precor Experience 700 Series Service Manual

Hide thumbs Also See for Experience 700 Series:
Table of Contents

Advertisement

Lift System Troubleshooting

The incline Lift system consists of an
an internal 1 K ohm potentiometer for lift position monitoring.
The first step in troubleshooting the lift system is to review the error log for any lift system
error codes. Then determine whether the problem is related to a lift movement issue or a lift
position sensor issue. If the lift does not move, then the problem is most likely related to
defective lift motor windings or the
platform position, then most likely the issue is due to a defective lift position sensor poten-
tiometer.
Use the lift motor related error codes 40 thru 45 to help isolate and repair the fault.
Related Error Codes
RELATED
ERROR CODE
40
No Lift Motion Detected
42
Lift Position Out Of Range
44
Un-commanded Lift Motion
45
Lift Moving In the Wrong Direction
Troubleshooting Procedure
Error code events are generated when the lift system has been commanded to move and no
and/or incorrect lift motion has been detected.
Review the machine Error Log or
codes (codes 40 thru 45). Then use the Error Code and Troubleshooting Guide to learn
about these error codes and procedures to troubleshoot and repair the issue, see
Code Troubleshooting
Operating the lift motor for troubleshooting
In normal operating mode, the treadmill requires the running belt to be moving to operate
the lift. Therefore, it is recommended to operate the lift motor from the service Hardware Val-
idation > Machine Test > Incline Test diagnostic test (see
Tests Menu (51765761)" on
1
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
2
Motor controller, motor controller unit, or motor controller module: used on treadmills, con-
tains the LPCA and motor controller functionality.
3
Touchscreen console Control Processing Assembly.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
1
AC
voltage driven lift motor (120 Vac or 240 Vac) and
2
MC
lift motor control circuitry. if the issue is with the lift
3
CPA
Event Log and note any lift system related error
Guide.
page 37) .
System Troubleshooting Procedures
DESCRIPTION
"Hardware Validation Diagnostics
7 Troubleshooting
Error
Page 268

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Experience trm700-16Experience trm700-18

Table of Contents