7. Connect the power cord and switch the power ON.
8. Verify the Drive Belt alignment and tension to specification. see
and Alignment Adjustment" on
9. Reinstall the hood cover, see
10. Do the Operation Verification tests (see
return to service.
Common Frame Drive Motor Replacement
Review entire procedure before starting.
Removal
1. Switch the power OFF and unplug the power cord.
2. Remove the hood cover, see
3. Disconnect the Motor Controller "MTH" and "MOTOR" electrical connections:
a. Remove the two left side MC fasteners and loosen the two right side fasteners.
Then slide the MC base to the left and remove the MC from the fasteners, see
"Motor Controller (MC) Replacement" on
b. Lift the front of the MC just enough to access and disconnect the MC "MTH" I/O
connector. Then lift the rear of the MC just enough to access and disconnect
the MC "MOTOR" I/O connector.
c. Remove the MOTOR interface cable from the three frame routing cable
clamps.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
page 58.
"Hood Cover Replacement" on
"Operation Verification" on
"Hood Cover Replacement" on
page 123.
6 Replacement Procedures
Drive Motor Replacement
"Drive Belt Tension
page 88.
page 24) and
page 88.
Page 160