7. Remove the four 1/2" hex head bolts, plastic top hat washers, and bottom washers
fastener hardware. Remove the drive motor. Retain part(s) and/or fastener(s) for
installation.
Installation Instructions
1. Install the replacement Drive Motor into the motor isolation tray and secure using the
four 1/2" hex fasteners, plastic top hat washers, and bottom washers fastener hard-
ware.
a. If you made a motor base install reference mark prior to removal, adjust the
Drive Motor base position to the motor base install reference mark and fully
tighten the four 1/2" hex head fasteners
b. If you did not make a motor base install reference mark prior to removal, pos-
ition the motor base to the rear tab stops (minimum belt tension position) and
fully tighten the four 1/2" hex head fasteners.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
6 Replacement Procedures
Drive Motor Replacement