On LED P10, P30, P30i and P31 consoles
a. Clear the Error Log of any stored error codes: Hold down PAUSE to access the
Error Log > select OK to view error codes, and then hold down QUICK START
to clear the Error Log of all error codes.
b. Clearing the Error Log resets the ASL and MC status lights. Verify that the ASL
status light is blue and the MC status light is green.
On touchscreen P62, P80, and P82 consoles
a. Clear the CPA Event Log: Access the service Settings menu (51765761),
select About > CPA Event Log. Then select the CLEAR softkey to clear the
CPA Event Log.
b. Reset the ASL status light: Access the service Settings menu (51765761),
select Maintenance > Operating Condition > Reset softkey to reset the ASL.
Verify the following Maintenance menu parameters:
Recommended Action: None
l
Operating Condition: Normal
l
Active Status Light: Solid Blue
l
c. Visually verify that the MC status light is now "green" and the ASL light is "solid
blue".
d. Exit and return to the "Welcome" banner home screen. select the Back softkey.
7. Reinstall the Hood cover, see
8. Do the Operation Verification tests (see
return to service.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
"Hood Cover Replacement" on
"Operation Verification" on
6 Replacement Procedures
Motor Controller (MC) Replacement
page 88.
page 24) and