1. Remove the hood cover, see
2. Use a 1/4" socket to loosen the right side power cord cable clamp fastener. Then
loosen the inner cable clamp fastener until the clamp can be slide over the power cord
socket.
3. Then disconnect and remove the power cord. In some cases the inner clamp fastener
may need to be completely removed. Retain part(s) and/or fastener(s) for installation.
Installation Instructions
1. Connect the replacement power cord socket into the Power Entry Assembly
input power connector.
2. Position power cord cable clamp over the power cord socket and fully tighten the
clamp fasteners.
3. Reinstall the hood cover, see
4. Connect the power cord and switch the ON/OFF circuit breaker ON.
5. Do the Operation Verification tests (see
return to service.
1
Alternating Current: electric current which periodically reverses direction between positive
and negative polarity.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
"Hood Cover Replacement" on
"Hood Cover Replacement" on
"Operation Verification" on