4.2 Connection of Control Unit

The method for connecting to each unit and device from the control unit is explained in this section.

4.2.1 Control Unit Connection System Drawing

Control unit
CG71
SIO
ENC
LCD
INV
Touch panel
I/F
MENUKEY
SKIP
OPT
RIO1
LAN
EMG
DCIN
Operation panel I/O unit
CG71
G011
cable
F034,F035
cable
R050,R054
cable
G023,G024
cable
Accessory cable for unit
Accessory cable for unit
Accessory cable for unit
Accessory cable for unit
R030
cable
cable
G395/G396/G380
R211
cable
cable
(
cross
)
G300
cable
F120
24VDC
cable
F070
Stabilized
power supply
E70 Series Connection Manual
4.2 Connection of Control Unit
RS-232C device
Synchronous feed encoder, or
5V manual pulse generator
Display unit
Skip input (Sensor input)
Servo/Spindle drive unit
Optical communication repeater unit
Remote I/O unit
MITSUBISHI CNC Machine operation panel
Ethernet device
Emergency stop signal