Sensitivity
Sensitivity stands for the percentage of the body part of an acceptable target that enters the
predefined region. Sensitivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predefined region. ST stands for the complete target body. The higher the value of
sensitivity is, the more easily the alarm can be triggered.
Threshold
The threshold for the time of the objects removed from the region. If you set the value as 10,
alarm is triggered after the object disappears from the region for 10s.
6. Optional: Repeat the above steps to set more regions.
7. For the arming schedule settings, see Set Arming Schedule . For the linkage method settings, see
Linkage Method Settings .
8. Click Save.
Note
The function is only supported by certain models. The actual display varies with the models.

6.2.9 Draw Area

This section introduces the configuration of area.
Steps
1. Click Detection Area.
2. Click on the live view to draw the boundaries of the detection region, and right click to complete
drawing.
3. Click Save.
Note
Click Clear to clear the selected area.
Click Clear All to clear all pre-defined areas.

6.2.10 Set Size Filter

This part introduces the setting of size filter. Only the target whose size is between the minimum
value and maximum value is detected and triggers alarm.
Steps
1. Click Max. Size, and drag the mouse in the live view to draw the maximum target size.
2. Click Min. Size, and drag the mouse in the live view to draw the minimum target size.
3. Click Save.