3 Servo Gun Setup wizard
3.3 Commissioning mode
Continued
Continues on next page
54
If previously loaded configuration file does not have the correct settings,
change them to the values that apply to your servo gun. For information
about the measurement system, see Application manual - Additional axes
and stand alone controller.
Active at Start Up and Disconnect at Deactivate only needs to be changed
if using a tool changer.
Tap Next.
xx1800000012
4 A restart is required for the changes to take effect. Tap Restart.
xx1700002051
5 After the restart, start the Servo Gun Setup wizard again.