10.2. Specifications
Item
General
Dimensions (W x L x H) mm
Weight
Housing material
Max. number of modules
Max. number of digital inputs
Max. number of analogue inputs
Max. number of digital outputs
Electrical
Internal current consumption at 24
VDC
Protection against polarity reversal
Loop through current between power
connectors
Operating voltage
Under-voltage detection
US1
Dropout voltage (sensors)
Max. current
Operating voltage
Under-voltage detection
US2
Dropout voltage
(valves/loads)
Max. current
Voltage drop to valve supply
Galvanic isolation
Maintenance alarm for the Fibre-optic
cable
Safe input
Number of inputs
Power supply voltages
Permissible supply voltage for
external supply
Power supply max current
Cross-circuit detection
Overload and short circuit protection
for UT1/UT2
Input type
Signal 1
Signal 0
Input current signal 1
Input characteristic
Table 10-1 specifications
EX245-FPS1
1,100 g or less
128 (independent of safe inputs)
64 (independent of solenoid valves)
350 mA or less
(via US1)
Yes (US1 and US2)
16 A (for US1 and US2)
24 VDC +20%/-15%
Detected: < approx. 20.4 VDC
Cancelled: > approx. 21.6 VDC
24 VDC +20%/-15%
Detected: < approx. 21.6 VDC
Cancelled: > approx. 22.8 VDC
4 A (independent of valves)
Max. 1.2 V at 24 VDC
Yes (between US1 and US2)
Yes
4 two-channel or 8 single-channel
Via UT1 or UT2 from US1
24 VDC +20%/-15%
2 A per power supply UT1
1 A per power supply UT2
Typ. 3.8 mA at 24 VDC
Complies with IEC 61131, type 3
- 51 -
Description
EX245-FPS2
85 x 148.5 x 136
Aluminium
8
8
300 mA or less (via US1)
10 A (for US1 and US2)
< approx. 17 VDC
6 A total
< approx. 17 VDC
-
3 A in total
Yes
Yes
PNP
11 to 30 V
-3 to 5 V
EX245-FPS3
1,200 g or less
No.EX##-OMY0004
Need help?
Do you have a question about the EX245-FPS1 and is the answer not in the manual?