Valve manifold connection
7.1.1.
Connect the valve manifold with the 2 screws on the SI Unit. (hexagonal socket wrench size 2.5)
Torque = 0.6 Nm
Caution
For a protection rating of IP65 to be ensured, apply the recommended tightening torque and make sure
that the O-ring is positioned correctly on the screw.
Module connection
7.1.2.
Connect the modules with the 2 modular adaptor assemblies and a joint assembly.
① 1 x Joint assembly
② 2 x Modular adaptor assembly (hexagonal socket wrench size 2.5, torque = 1.3 Nm)
Caution
For a protection rating of IP65 to be ensured, modular adaptor assemblies and joint assembly must be
installed between each module correctly.
To prevent the modules and assemblies being damaged, apply the recommended tightening torque.
Fig. 7-2 Valve manifold connection
Fig. 7-3 Module connection
- 26 -
O-ring
No.EX##-OMY0004