Code
Type
2172
Error
2173
Error
2174
Error
2175
Error
2176
Error
2177
Error
2178
Error
2179
Error
2180
Error
2181
Error
2183
Error
180
Possible cause
Stepper motor card X30
motor overload / overvoltage
/overcurrent (Stitch length)
Stepper motor card X30
Sewing motor encoder not
connected (Stitch length)
Stepper motor card X30
Sewing motor encoder not
init (Stitch length)
Stepper motor card X30 Init
Position not found (Stitch
length)
Stepper motor card X30 not
Enabled (Stitch length)
Stepper motor card X30
Overload (Stitch length)
Stepper motor card X30
Encoder failure (Stitch
length)
Stepper motor card X30
Current sensor failure (Stitch
length)
Stepper motor card X30
Incorrect stepping motor
direction of rotation (Stitch
length)
Stepper motor card X30
Reference drive failure
(Stitch length)
Stepper motor card X30
overcurrent (Stitch length)
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Remedial action
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
• Replace control
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace encoder
• Replace control
• Replace encoder
• Check if plugs have been mixed up
• Check the wiring in the machine
distributor and change it if necessary
• Check for stiff movement
• Replace encoder
• Replace motor
• Replace control
Troubleshooting