Dürkopp Adler D669 Operating Instructions Manual page 117

M-type delta
Table of Contents

Advertisement

Programming
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Setting options Stitch length
Menu item Setting 1
linear
Stitch length
Value range -50 – 50 [%]
Min. Material
thickness
Value range 00.0 – 10.0 [mm]
Max. Material
thickness
Value range 00.0 – 10.0 [mm]
2.Value
Min. Material
On/Off
thickness
Value range 00.0 – 10.0 [mm]
2. Value
Min. Material
On
thickness
Value range 00.0 – 10.0 [mm]
Setting 2
Maximum stitch length vari-
ation reached at the upper
material thickness limit.
Material thickness at which
the increase/reduction of
stitch length should start.
Material thickness up to
which the increase/reduc-
tion of stitch length should
occur.
Material thickness from
nd
which the 2
stitch length
should be used.
Material thickness from
nd
which the 2
stitch length
should be used.
115