Code
Type
2385
Error
2387
Error
2388
Error
2401
Error
2405
Error
2421
Error
2422
Error
2430
Error
2431
Error
2471
Error
2472
Error
2473
Error
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Possible cause
Stepper motor card X50
insulation error (Sewing foot
stroke)
Stepper motor card X50
transport interval failure
(Sewing foot stroke)
Stepper motor card X50
Reference drive failure
(Sewing foot stroke)
Stepper motor card X60
reference run timeout
(Edge guide)
Stepper motor card X60
stepper motor blockage
(Edge guide)
Stepper motor card X60
encoder plug (Sub-D, 9-pin)
not connected
Stepper motor card X60
flywheel position not found
Stepper motor card X60 not
responding
Stepper motor card X60
parameter init error
Stepper motor card X60
Watchdog (Edge guide)
Stepper motor card X60
motor overload / overvoltage
/overcurrent (Edge guide)
Stepper motor card X60
Sewing motor encoder not
connected (Edge guide)
Remedial action
• Check motor phase and PE for low-
impedance connection
• Replace encoder
• Replace sewing motor
• Perform a software update
• Check selection of class
• Check for stiff movement
• Replace encoder
• Replace motor
• Check reference sensor
• Check for stiff movement
• Connect encoder cable to the control,
use the correct interface
• Check stepper motor 1 for stiff movement
• Perform a software update
• Replace control
• Perform a software update
• Check selection of class
• Perform a software update
• Check selection of class
• Check selection of class
• Replace control
• Replace encoder
• Replace stepper motor
• Replace control
185