Troubleshooting
Code
Type
6364
Information No valid data on internal
6365
Information Internal EEprom defective
6366
Information Internal EEprom defective
6367
Information Internal EEprom defective
7270
Information External CAN
9310
Error
9320
Error
9330
Information Material thickness sensor
9340
Error
9910
Warning
9911
Warning
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Possible cause
EEprom and no external
EEprom connected (the
internal data structures are
not compatible with the
external data storage
device)
and external data not valid
(emergency operating
features only)
and external data not valid
(emergency operating
features only)
Tape feeder not connected
Tape feeder in lowered
position
not connected
Remaining thread monitor
not connected
Sewing stop
Power down
Remedial action
• Check machine ID connection
• Switch off the control, wait until the LEDs
have gone out, and then switch on the
control again
• Software update
• Replace control
• Replace control
• Replace control
• Check connection cables
• Perform a software update
• Replace CAN slaves
• Check connection cables
• Perform a software update
• Replace the control of the tape feeder
• No remedial action entered in translation
table
• Check connection cables
• Perform a software update
• Replace material thickness sensor
• Check connection cables
• Perform a software update
• Replace remaining thread monitor
• Check tilt sensor on machine
• Check 24V
• Replace control
• The control is switched off