Dürkopp Adler D669 Operating Instructions Manual page 180

M-type delta
Table of Contents

Advertisement

Code
Type
1004
Error
1005
Error
1006
Error
1007
Error
1008
Error
1010
Error
1011
Error
1012
Error
1054
Error
1055
Error
1060
Error
1061
Error
178
Possible cause
Incorrect sewing motor
direction of rotation
Motor blocked
Maximum speed exceeded
Error in the reference run
Sewing motor encoder error • Replace encoder
External synchronizer plug
(Sub-D, 9-pin) not
connected
Encoder Z pulse missing
Synchronizer fault
Internal short circuit
Sewing motor overload
Sewing motor overload /
overvoltage /overcurrent
Sewing motor overload /
overvoltage /overcurrent
Operating Instructions D669 M-TYPE DELTA - 00.0 - 10/2020
Remedial action
• Replace encoder
• Check motor plug assignment and
change it if necessary
• Check wiring in machine distributor and
change it, if necessary
• Test motor phases and check for correct
value
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Replace encoder
• Perform reset
• Check class (t 51 04)
• Replace encoder
• Check for stiff movement
• Connect cable of external synchronizer to
control, make sure that interface (Sync) is
correct
• Only recommended for machines with
transmission!
• Switch off the control, use handwheel to
turn, and switch on the control again
• If error is not corrected, check encoder
• Replace synchronizer
• Replace control
• Check for stiff movement
• Replace encoder
• Replace sewing motor
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
• Check selection of class
• Replace control
• Replace motor
• Replace encoder
Troubleshooting