CameraLink Area Scan Camera·User Manual
When the camera's temperature is higher than the threshold you set, fan starts to work. When
the camera's temperature is 5 °C (41 °F) lower than the threshold you set, fan stops working.
Only type II camera and type III camera have fan.
9.3 Save and Load User Set
The camera supports 4 sets of parameters, including 1 default set and 3 custom sets. The relation
among 4 sets of parameters is shown below.
Figure 9-2 Parameter Relation
You can save parameters, load parameters and set user default as shown below.
Save Parameters
Steps:
1. Click User Set Control, and select a user set in User Set Selector. Here we take selecting User
Set 1 as an example.
2. Click Execute in User Set Save to save parameters.
Figure 9-3 Save User Set