9.4 Set Transport Layer Control
You can go to Transport Layer Control to view the camera's load size, tap configuration mode,
GenCP version, etc. The specific parameters in Transport Layer Control interface and output order
of different taps are shown below.
Parameter
Paylode Size
Device Tap Geometry
CI Configuration
GenCP Version Major
GenCP Version Minor
Supported Baudrates
When Device Tap Geometry is Geometry_1X_1Y, the output order of tap is shown below.
CameraLink Area Scan Camera·User Manual
Table 9-2 Transport Layer Control Parameter Description
Read/Write
Read only
Read and write
Read only
Read only
Read only
Read only
Figure 9-6 Geometry_1X_1Y
Description
It is the camera's load size.
The value of camera sensor geometry in the
frame grabber software should be the same
with that of Device Tap Geometry.
Inconsistent parameters may lead to image
exception. You can select different tap
numbers by clicking Transport Layer Control >
Device Tap Geometry.
It is the configuration mode. It switches
automatically in accordance with different tap
configuration mode. You can select different
frame grabber configuration modes by clicking
Transport Layer Control > CI Configuration.
It is the major version in GenCP version.
It is the minor version in GenCP version.
It displays the supported baud rates.