7.5.2
Requirements for PROFIsafe communication
Requirements for PROFIsafe communication
The following minimum software and hardware requirements apply for the configuration and
operation of safety-oriented communication (F communication):
Software tools:
● SIMATIC Manager STEP 7 V5.4 SP4
● S7 F Configuration Pack V5.5 SP3
● S7 Distributed Safety Programming V5.4 SP3
● STARTER V4.1.5 + SSP V4.3 or SIMOTION SCOUT V4.1.5 + SSP V4.3 or higher
● Drive ES Basic V5.4 SP4
● SINAMICS Firmware version 4.3 or higher
Hardware:
● A controller with safety functions (in our example, SIMATIC F-CPU 317F-2
● SINAMICS S120 (in our example, a CU320-2)
● Correct installation of the devices
Safety Integrated
Function Manual, (FHS), 11/2009, 6SL3097-4AR00-0BP0
When using a SIMATIC F-CPU
1)
NOTICE
If only one software tool or one hardware component is older than specified in this
document or is missing, then PROFIsafe cannot be configured via PROFIBUS or
PROFINET.
or higher
1
or higher
1
or higher
1
or higher
1
Commissioning
7.5 PROFIsafe via PROFINET
)
1
157