Safety Integrated Functions Parameterized Via Tm54F - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

9.2.2.3

Safety Integrated functions parameterized via TM54F

Parameters for control by way of TM54F
Table 9- 7
SI function
Sampling time
Monitoring time discrepancy *
Forced dynamic behavior timer
Input terminal
Forced dynamic behavior
F-DO 0...3
TM54F operating mode
Special operation mode selection
Emergency Stop stop response
STO input terminal
SS1 input terminal
SS2 input terminal
SOS input terminal
PLC input terminal
EMERGENCY STOP input terminal
F-DI input mode
F-DI test enable
F-DO 0 signal sources
F-DO 1 signal sources
F-DO 2 signal sources
F-DO 3 signal sources
Test sensor feedback
input DI 20...23
* Additional important information can be found in Chapter "Input/output interconnections of a
safety switching device with TM54F".
Safety Integrated
Function Manual, (FHS), 11/2009, 6SL3097-4AR00-0BP0
Parameters for control via the TM54F (excerpt)
Acceptance tests and acceptance reports
Parameters
p10000
p10002
p10003
p10007
p10008
p10020[0...3]
p10021[0...3]
p10022[0...3]
p10023[0...3]
p10024[0...3]
p10025[0...3]
p10026[0...3]
p10038[0...3]
p10040[0...3]
p10041
p10042[0...5]
p10043[0...5]
p10044[0...5]
p10045[0...5]
p10046[0...5]
9.2 Acceptance reports
Value
12.00 ms
12.00 ms
8.00 h
0
1
1
0
0
0
0
0
0
0
0
0000 bin
0
0
0
0
0
189