Preconditions For The Safety Extended Functions - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

2.2

Preconditions for the Safety Extended Functions

● A license is required to use the Safety Integrated Extended Functions. The associated
● Control via PROFIsafe or TM54F
● An activated speed controller in the drive
● Overview of hardware components that support the Extended Functions:
Safety Integrated
Function Manual, (FHS), 11/2009, 6SL3097-4AR00-0BP0
license key is entered in parameter p9920 in ASCII code. The license key is activated
using parameter p9921 = 1. For information on how to generate the license key for the
product "SINAMICS Safety Integrated Extended Functions", read the section "Licensing"
in the SINAMICS S120 Function Manual. An insufficient license is indicated via the
following alarm and LED:
– A13000 --> License not sufficient
– LED RDY --> Flashes greed/red at 0.5 Hz
– Control Unit CU320-2
– Motor Modules Booksize where the order number ends as follows: ...3 or higher
– Motor Modules Booksize Compact
– Motor Modules Chassis where the order number ends as follows: ...3 or higher
– Motor Modules Cabinet where the order number ends with ...2 or higher
– Power Modules Blocksize
– Control Unit adapter CUA31 with order no.: 6SL3040-0PA00-0AA1
– Control Unit adapter CUA32 with order no.: 6SL3040-0PA01-0AA0
– Sensor Module SMC20, SME20/25/120/125, SMI20
– Motors with integrated encoder and encoder evaluation with DRIVE-CLiQ interface
General information about SINAMICS Safety Integrated
2.2 Preconditions for the Safety Extended Functions
37