Setting Up Inputs And Outputs - GE DigitalFlow XGS868i Programming Manual

Panametrics steam ultrasonic mass flow transmitter
Table of Contents

Advertisement

C.6.1c
Selecting Mass Flow Units
1. Double-click on the desired Mass Flow units for flow rate display (listed in Table 22).
2. Double-click on the desired Mass Flow Time units (from seconds to days).
3. Double-click on the desired number of MDOT Dec. Digits (digits to the right of the decimal point) in the mass flow
rate display.
4. Double-click on the desired Mass Totalizer (units for the totalized mass flow rate display, listed in Table 22).
5. Double-click on the desired number of Mass Decimal Digits (digits to the right of the decimal point) in the
totalized mass flow rate display.
The XGS868i returns to the Global PROGRAM window. Click [Exit Page] to return to the Site Edit Menu.
You have completed entering selections in this option.The program returns to the Global PROGRAM menu.
C.6.2 Setting Up Inputs and Outputs
Set up the XGS868i's inputs and outputs via the
Figure 55 on page 142 in Appendix D, PanaView Menu Maps. Remember to record all programmed data in Appendix
B, Data Records.The I/O submenu consists of the following options:
Error Handling
- program the meter's response during an error condition
- set up any option cards and the
Options
- set up the LCD display.
Display
I/O
To enter the
submenu:
1. In the Site Data Menu, double-click on the Global entry.
2. Highlight and double-click on the
Note: In this section,
Slot 1
DigitalFlow™ XGS868i Programming Manual
Table 22: Available Mass Flow Units
English
Pounds
KiloPounds
(Thousands of Pounds)
MillionPounds
TONS (2000 LB)
I/O
Slot 0
Input/Output
appears as an option only if a suitable option card is installed in Slot 1.
Appendix C. Programming the XGS868i Using PanaView™
Metric
Kilograms
Tonne = Metric Tons (1000 KG)
submenu. While following the programming instructions, refer to
analog outputs
option in the center pane.
113