GE DigitalFlow XGS868i Programming Manual page 43

Panametrics steam ultrasonic mass flow transmitter
Table of Contents

Advertisement

1.9.2g Totalizer Outputs (cont.)
Setting Up the Totalizer
1. Scroll to the desired Channel option and press [Enter].
2. Scroll to the desired Measurement parameter and press [Enter]. See Table 10 below for a list of the available
options.
Note: The measurement units that appear in these prompts are those selected in the
this section.
3. Use the arrow keys to enter a value for the minimum Pulse On time (between 1 sec and 10,000 sec) for the
frequency of the totalizer pulses and press [Enter].
Note: A complete pulse consists of equal amounts of ON and OFF times. Choose a value that is compatible with the
frequency counter to be used.
4. Use the arrow keys to enter a value for the number of measurement units represented by each pulse and press
[Enter].
Procedure Options
After completing the above steps, the XGS868i returns to the I/O window. Do one of the following:
To continue programming, refer to Appendix A, Menu Maps, to navigate to the desired menu.
To leave the Keypad Program, press [Escape] four times.
DigitalFlow™ XGS868i Programming Manual
Table 10: Output Measurement Options
Forward Totalized Volume Flow
Reverse Totalized Volume Flow
Forward Totalized Mass Flow
Reverse Totalized Mass Flow
Chapter 1. Programming Site Data
Global-System
window earlier in
33