GE DigitalFlow XGS868i Programming Manual page 160

Panametrics steam ultrasonic mass flow transmitter
Table of Contents

Advertisement

Appendix F. Foundation Fieldbus Tables
Table 33: GE Fieldbus Device Capability, XGX868 Family of Meter Types (cont.)
1.17
Meter Software version (minimum and higher)
1.18
Firmware on FF card version
1.19
Interoperability Test Kit (ITK) revision
1.2
Protocol
1.21
Protocol Baud (bps)
2 - DD and CFF
2.1
Device Description File Name (.ffo and .sym) and rev
2.2
Capabilities File Name and rev
2.3
Methods (list all methods available)
3- Physical
3.1
Polarity Sensitive (Yes / No)
3.2
Quiescent Current Draw (mA)
3.3
Startup Current Draw (ma)
3.32
Working voltage
3.33
Device Minimum Voltage
3.41
Device Resistance (Ohms) fieldbus terminal (+) to (-)
3.42
Device Resistance (Ohms) fieldbus terminal (+) to
Ground
3.43
Device Resistance (Ohms) fieldbus terminal (-) to
Ground
3.51
Capacitance (microF) (+) to (-)
3.52
Capacitance (microF) (+) to Ground
3.53
Capacitance (microF) (-) to Ground
3.6
4-wire Device (if so, what AC/DC Voltage, Single or
3-phase
3.7
Connection type
4 - Comm
4.1
Stack Manufacturer
4.2
Does the Device support Backup LAS functionality?
(If it does, then the functionality will be tested.)
4.3
4.4
Total Number of VCRs
4.5
Number of Fixed VCRs for user configuration
(Publisher, Subscriber, Alarming, and Trending)
150
GF868: GF3S; GM868:GM3Q; GS868: GS3N;
GC868: GC4C; XGM868i: Y4DM; XGS868: Y4DS;
XGF868i:Y4DF
868_GAS_FF_206
6.1.1
H1
31.25k
0203
020101.cff
none
Yes (Protected from failure if installed
incorrectly)
10 mA idle / 18 mA max
18 mA
9-32 VDC
9 VDC
30 Mega Ohms increasing
open circuit > 20 MOhm
open circuit > 20 MOhm
1 pF
634.7 pF
635.7 pF
Yes, (85-250 VAC 50/60 Hz, single phase or
12-28 VDC)
Terminal block, 2-wire twisted pair
National Instruments
No
20
1 fixed for System Management,
19 variable for user configuration
DigitalFlow™ XGS868i Programming Manual

Advertisement

Table of Contents
loading

Table of Contents