Table 48: Specific technical data DXC-EXT-IO...
Technical data
Input voltage
DXC-EXT-IO110
DXC-EXT-IO230
High signal
DXC-EXT-IO110
DXC-EXT-IO230
Degree of protection (without
the connection pins being
covered by the DC1's control
signal terminal block)
For detailed instructions on how to install the expansion
modules, please refer to instruction leaflet IL04012016Z.
NOTICE
Internal relay K1 is looped with the expansion module, meaning
it can only conduct a lower current (≦ 1 A).
DANGER
Dangerous voltage!
Expansion modules DXC-EXT-IO110 and DXC-EXT-IO230 must
not be placed into operation until all mounting and installation
work has been completed. Any other use will be considered to
be an inappropriate use.
DC1...20... and DC1...OE1 Variable Frequency Drives 02/20 MN040059EN www.eaton.com
Unit
Value
V
100 - 10 % - 120 + 10 %, 50/60 Hz
(90 - 132 ± 0 %, 48 - 62 Hz ± 0 Hz)
V
200 - 10 % - 240 + 10 %, 50/60 Hz
(180 - 264 ± 0 %, 48 - 62 Hz ± 0 Hz)
V
80 - 250 , R
≈ 68 kΩ
i
V
80 - 250 , R
≈ 68 kΩ
i
IP00
7 Accessories
7.1 Device-specific accessories