6.2 Specific rated operational data
The following tables list the specific rated operational data for the individual
DC1 series based on the corresponding rated operational current.
Examples
DC1- 1D
2D3 ...
Rated operational current (2D3 ≙ 2.3 A)
DC1 series
(1D = Single-phase mains connection, 115 V, with voltage doubler)
D C1 - 1 2
7D0
F B
D C 1 - 3 2
0 4 6 ...
Rated operational current (046 ≙ 46 A)
DC1 device series
(32 = three-phase mains connection, 230 V)
(34 = three-phase mains connection, 400 V
DC1...20... and DC1...OE1 Variable Frequency Drives 02/20 MN040059EN www.eaton.com
...
Power section characteristics
NN = without radio interference suppression filter, without brake chopper
FN = with radio interference suppression filter, without brake chopper
NB = without radio interference suppression filter, with brake chopper
FB = with radio interference suppression filter, with brake chopper
Rated operational current (7D0 ≙ 7.0 A)
DC1 device series
(12 = single-phase mains connection (230 V)
6 Technical Data
6.2 Specific rated operational data
)
149