10.3

Status display

10.3.1

Setting TPM lights

The TPM lights are visible in the status bar of the "Machine" operating area.
Per default, the TPM lights are not visible and must be activated in the "slmahdconfig.ini" file.
You can change the default values and specify which light color is displayed for each value
in the data block.
Entries in the "slmahdconfig.ini" file
Entries
TPM
TPMGreen
TPMYellow
TPMRed
TPMPLCData
Procedure
1. Copy the "slmahdconfig.ini" file from the /Siemens/sinumerik/hmi/cfg directory.
2. Store the file in the /Oem/sinumerik/hmi/cfg or /User/sinumerik/hmi/cfg directory.
3. Open the file and make the required settings.
"slmahdconfig.ini" file
[TPM]
TPM=0
TPMGreen=1
TPMYellow=2
TPMRed=3
TPMPLCData=DB59.DBB800
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
Meaning
1 = Lights on
0= Lights off (default)
1 = Value of the data block for "green light" (default)
2 = Value of the data block for "yellow light" (default)
3 = Value of the data block for "red light" (default)
Data block to be evaluated, e.g. DB59.DBB800