Siemens SINUMERIK 840D sl Commissioning Manual page 138

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Configuring alarms
14.3 Configuring an alarm log
Log all alarms with the SourceURL "/NCK" or "/HMI":
<CONFIGURATION>
<Protocol>
<Filters>
</Filters>
</Protocol>
</CONFIGURATION>
Log all alarms with a "SEVERITY greater than 10" and "less than 500":
<CONFIGURATION>
<Protocol>
<Filters>
</Filters>
</Protocol>
</CONFIGURATION>
Note
The "Siemens_Filter_01" filter is reserved for Siemens.
1. In the <FilePath> tag, adapt the path and file name for the file in which the alarm log is
<CONFIGURATION>
<Protocol>
value="$(HMI_INSTALL_DIR)user/sinumerik/hmi/
</Protocol>
</CONFIGURATION>
● Path
● File name:
132
<Filter_01 type="QString" value="SourceURL EQUAL /NCK" />
<Filter_02 type="QString" value="SourceURL EQUAL /HMI" />
<Filter_01 type="QString" value="SEVERITY HIGHER 10 AND
stored persistently:
<Filters>
<FilePath type="QString"
</Filters>
Environment variables can also be incorporated in the path, e.g. for the installation
directory of the HIMI sl: $(HMI_INSTALL_DIR).
A 3-digit number and the file extension "hmi" are automatically added to the specified file
name during operation, e.g. "slaepp_123.xml". The number is automatically increased
when:
– The file has reached the maximum size (DiskCare = 0), or
– the specified period has elapsed (DiskCare > 0).
Older files are deleted.
NOTICE
The CompactFlash card only allows a limited number of write cycles! Therefore,
ensure that the storage is only performed when there is a justifiable need! The alarm
log is not saved in the default configuration.
SEVERTY LOWER 500" />
log/alarm_log/slaepp_"/>
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0