9.5
Displaying/editing drive parameters
The "Control Unit MD", "Infeed MD" and "Drive MD" softkeys are available for the display
and for the purpose of editing drive parameters.
A separate list display is provided for each of these areas in which you can view and edit
drive data.
Requirement
Settings on drive parameters are protected with protection level 1 (password: Machine
manufacturer).
Please refer to the following documentation for information about commissioning the drive
parameters:
References
CNC Commissioning Manual: NCK, PLC, drives
Procedure
9.6
Machine data display filter
Through the use of the machine data display filter, it is possible to reduce the number of
displayed machine data relating to a certain area, e.g. general machine data, for special
purposes.
Machine data areas
Display filters are available for the following machine data areas:
● General machine data
● Channel-specific machine data
● Axis-specific machine data
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
1.
Select the "Startup" operating area.
2.
Press the "Mach. data" softkey.
The softkeys "Control Unit MD", "Supply MD", and "Drive MD" are
displayed.
3.
Press the sofkey of an area to show its parameters.
Machine and setting data
9.5 Displaying/editing drive parameters