Machine and setting data
9.7 Editing machine data and drive parameters
9.7
Editing machine data and drive parameters
9.7.1
Editing hexadecimal values
You can use a bit editor to enter the required values for machine data in hexadecimal format.
Procedure
52
1.
Select the "Startup" operating area.
2.
Press the "Mach. data" softkey and select the required machine data
area (e.g. general machine data).
3.
Position the cursor on the entry to be edited.
4.
Press the "SELECT" or "INSERT" key.
The "Bit Editor" window opens.
All bits of the machine data item that have a description text are
displayed.
5.
If you activate the "Display all bits" checkbox, all bits regardless of
their data type (8, 16 or 32 bits) are displayed. Activate the relevant
bit.
6.
Press the "OK" softkey. The setting is checked and an error message
may be output.
The window closes and you return to the machine data overview.
The new value is displayed in hexadecimal format.
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
HMI sl (IM9)