Configuring The User Status Display - Siemens SINUMERIK 840D sl Commissioning Manual

Hmi-embedded im2
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

They are still to be found under different paths, divided into write-protected (standard) and
user-specific areas.
Standard (write-protected)
The write-protected standard icons are stored in folders (icoxxx) using the following path:
/siemens/sinumerik/hmi/ico/icoxxx/
xxx stands for the relevant resolution, "640", "800", "1024", see table above.
User
The user-specific icons are stored in folders (icoxxx) in the following three subdirectories:
Standard expansion (AddOn projects)
Vendor
User
In-house configuration
Files with the configured screen definition "Expanding the user interface" (wizard "com files"
including icons) are located in folders:
/oem/sinumerik/hmi/proj
/user/sinumerik/hmi/proj
Please refer to the sub-book for a detailed description on how to configure bitmaps and
icons:
References
Supplement user interface (BE1)
4.5.2

Configuring the user status display

General
Machine states controlled by the PLC can be displayed in the program status bar via user
icons.
The display of user symbols (icons) must be activated using the display machine data
MD9052 $MM_SHOW_CHANNEL_SPANNING_STATE spanning state.
The program path of the currently selected program is then displayed in the bar underneath,
together with the program name.
16 display positions are defined in the program status bar.
Commissioning HMI-Embedded (IM2)
Commissioning Manual, 01/2008, 6FC5397-8CP10-1BA0
Creating user-specific alarm texts
/addon/sinumerik/hmi/ico/icoxxx
/oem/sinumerik/hmi/ico/icoxxx
/user/sinumerik/hmi/ico/icoxxx