Backing Up The Hardware Configuration - Siemens SINUMERIK 840D sl Commissioning Manual

Base software and hmi sl
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

15.3

Backing up the hardware configuration

The hardware is configured via the system data blocks (SDB) and only these are stored in
the archive.
Procedure
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
3.
Press "OK".
The "Series Startup" window opens.
4.
Activate the "Read in series startup" checkbox. The "Select Startup
Archive" window opens and the data tree is displayed.
5.
Select the desired startup archive (ARC).
6.
Press the "OK" softkey.
A safety query prompting whether you really want to perform a series
machine startup appears.
7.
Press the "OK" softkey.
The "Read In Archive" window opens and a progress message box
appears for the read-in process.
8.
Press the "Cancel" softkey to cancel the read-in process.
1.
Select the "Startup" operating area.
Press the menu forward key.
2.
Press the "Series startup" softkey.
The "Series Startup" window opens.
3.
Select "Create PLC hardware upgrade archive (SDBs only)" and press
the "OK" softkey.
The "Create PLC hardware upgrade archive (SDBs only): Select
archiving" window opens.
4.
Select the desired storage location in the displayed data tree.
- OR -
15.3 Backing up the hardware configuration
Data backup
145

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents