Commissioning a System

1.4 Meaning of switch positions

Booting up the basic system
RDY LED:
Other LEDs:
Meaning:
NRK/NCK outputs
RDY LED:
Other LEDs:
Meaning:
System error
RDY LED:
Other LEDs:
Meaning:
RDY LED:
Other LEDs:
Meaning:
1.4
Meaning of switch positions
Overview
The NCU has two twist buttons in the lower section of the front panel.
● NCK start-up switch with label SIM/NCK
● PLC mode selector switch with label PLC
The switch positions are marked with even numbers or letters; the uneven numbers are
represented by dots due to space limitations.
8
Slowly flashing yellow/green (0.5Hz)
Set by PLC/option module
Phase 3: Initialization of the basic system
OFF (if fault status: red)
Set by PLC/option module
After the basic system, the NRK/NCK takes over the LED and
7-segment display.
Rapidly flashing red (2Hz)
Set by PLC/option module
An error has occurred.
The system is stopped.
Rapidly flashing red/yellow (2Hz)
Set by PLC/option module
An error has occurred.
The system has continued running - although with restricted
functions.