15.5

Reading in an archive with original data

The data of the original control state is stored in the "original.arc" file. If you want to restore
the controller to the as-delivered state, you can read in the original data archive.
Requirement
You will need access rights for protection level 3 (password: End user).
Procedure
HMI sl (IM9)
Commissioning Manual, 01/2008, 6FC5397-1DP10-3BA0
1.
Select the "Startup" operating area.
2.
Press the menu forward key.
3.
Press the "Series startup" softkey.
The "Series Startup" window opens.
4.
Activate the "Read in archive of original status" checkbox and press
the "OK" softkey. HMI sl automatically accesses the "original.arc" file.
A window opens prompting whether you want to perform a series
startup.
5.
Press the "OK" softkey.
The read-in process is started and a progress message box is
displayed in the window.
Any errors that occur are then displayed in the "Write Error Log for
Archive" window.
15.5 Reading in an archive with original data