Status reporting
not finished reading a response (from the Output Queue) and is already sending new data.
Lastly, Query Error is reported when there is a Deadlock situation: Output Queue and
Input Queue are both full. This situation is unlikely to happen due to the Input Queue
being able to hold several Commands and Queries.
Standard Event Status Enable Register - set with *ESE read
with *ESE?
PON
The Register has the same structure as the Standard Event Status Register.
Performing a bit by bit AND between the Event Register and the Event Enable Register
and then ORing the resulting bits, generate the Status Summary Message ESB (Event
Summary Bit).
Setting new value to the Register causes a re-calculation of ESB and <rqs>.

Primary Status Register - read with PSR?

PRIM
OT
PRIM_OT ........Primary Over Temperature.
PRIM_FLT ......Primary is faulty (its output is down).
EXT_SHUT .....Primary is shutdown by user (external signal).
P_M_SHUT .....Primary is shutdown by a Power Module.
PRIM_SHUT ...Primary is shutdown due to Power Error or Channel Fault.
PWR_ERR.......Primary Power Envelope exceeded - shutdown.
PWR_WRN .....Primary Power Envelope exceeded - warning zone.
PRIM_INP .......Primary input error (power fail).
The Primary Status Register shows the current status of the Primary.

Primary Event Status Register - read with PER?

PRIM
OT
The Primary Event Status Register has the same structure as the Primary Status Register.
The bits in the Event Register are "sticky" - once a bit is set it will remain set even if the
condition that caused it to be set is no longer valid.
The register is cleared when read and <rqs> and <ist> are re-calculated.
Primary Event Status Enable Register - set with PEE, read
with PEE?
PRIM
OT
The Primary Event Status Enable Register has the same structure as the Primary Status
Register.
The Status Summary Message PRIM_ERR is calculated by performing a bit by bit AND
between the Primary Event Status Register and the Primary Event Status Enable Register
and then ORing the resulting bits.
0
CME
EXE
PRIM
EXT
P_M
FLT
SHUT
SHUT
PRIM
EXT
P_M
FLT
SHUT
SHUT
PRIM
EXT
P_M
FLT
SHUT
SHUT
XMP 2600 Programming Manual
IEEE 488.2 compatible Status Structures
DDE
QYE
PRIM
PWR
SHUT
ERR
PRIM
PWR
SHUT
ERR
PRIM
PWR
SHUT
ERR
rev. 1.1
0
OPC
PWR
PRIM
WRN
INP
PWR
PRIM
WRN
INP
PWR
PRIM
WRN
INP
73